PVC Insulation Compound JH-I70E

Flexible PVC insulation granules for 450/750 V wires and cables. Positioned for stable extrusion and electrical insulation, with final electrical values confirmed by sample batch or customer-side testing.

Send RFQRequest TDS

PVC insulation compound granules

Typical uses

Insulation for low-voltage wires and cables, 450/750 V and below.

Color: customer color
Packing: 25 kg bag
Trial quantity: Confirm after reviewing the trial

Custom matching

For electrical-critical applications, send target standard, conductor size and wall thickness. Sample batch testing is recommended before mass production.

Sample policy

Samples require sample fee + courier fee paid in advance.

Specification checklist

PropertyTo confirm for your application
HardnessConfirm buyer target or approved sample before trial
Volume resistivity at 20 CName the method, specimen, conditioning and acceptance criterion
Dielectric strengthName the method, specimen geometry and acceptance criterion
Temperature ratingConfirm the applicable wire or cable standard and clause
Processing temperatureSet from the actual compound, conductor, screw, die and line trial
NoteElectrical values require an identified sample lot and traceable test record

Match the wire or cable application

Start with the wire construction and the applicable specification. This is an insulation material inquiry route; a cable voltage designation does not establish a measured dielectric result or finished-wire approval. Keep raw compound checks, insulated-specimen tests and finished-wire tests separate.

Prepare the material brief

Agree the sample decision

  1. Agree what is being tested

    Identify the material lot, test object, method and acceptance criteria before preparing a sample.

  2. Record the controlled trial

    Keep the conductor, insulation thickness and line conditions with the sample record. Compare the result under agreed conditions.

  3. Review before production

    Review the available test records and processing feedback. Confirm the production specification and the shipment checks separately.

Documents to review

Ask for the current TDS status and identify which entries are development targets. A batch COA needs actual results for the named lot. An empty COA template is not a test report. An official SDS, third-party report or certification statement is offered only after the applicable original document and scope have been reviewed.

Purchasing questions

Does the voltage in the application replace testing?

No. The relevant wire construction, standard and test evidence must be confirmed. No electrical pass is inferred from the product name.

Can I use a jacket compound as insulation?

Do not treat the two inquiry routes as interchangeable. State the layer and electrical requirements so the sample and tests can be reviewed.

What if I do not have a complete specification?

Send a drawing or current sample and explain the intended wire and market. Missing test requirements must be clarified before agreeing an acceptance result.